Effectiveness of automatic FiO₂ control devices in the neonatal intensive care unit: a literature review

Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Published: 26 August 2026
0
Views
0
Downloads

Authors

Introduction: respiratory failure in newborns frequently requires oxygen therapy as a fundamental intervention. However, the use of high concentrations of oxygen exposes the newborn to high oxidative stress and increases the risk of developing numerous chronic conditions. This article aims to summarize the scientific literature on the actual effectiveness of devices for the automatic management of delivered FiO2, specifically the actual effectiveness of this technology in maintaining the patient within predefined saturation targets while reducing periods of hyperoxia or hypoxia.

Materials and Methods: a literature review was conducted using the online databases Medline (for PubMed), the Cochrane Library, and EBSCO (for CINAHL). Articles addressing outcomes other than the efficacy criteria of the research objective were excluded; only English-language articles published within the last 10 years were selected.

Results: the literature indicates that the use of devices for automatic FiO₂ titration in newborns receiving oxygen therapy increased the time spent within the set saturation target range, thereby reducing periods of hypoxia or hyperoxia.

Conclusions: this review demonstrates the effectiveness of automatic devices (Closed-Loop Automated Oxygen Control, CLAC). Further studies are needed to identify an optimal target saturation range, in order to properly guide clinical practice in oxygen administration. Although the use of CLAC has been shown to be effective in maintaining normal saturation targets, further follow-up studies are needed to demonstrate that the use of CLAC is truly effective in reducing hyperoxia-related complications.

Downloads

Download data is not yet available.

Citations

1. Sturrock S, Ambulkar H, Williams EE, et al. A randomised crossover trial of closed loop automated oxygen control in preterm, ventilated infants. Acta Paediatrica 2021;110:833–7.
2. Mitra S, McMillan D. Automated control of fraction of inspired oxygen: is it time for widespread adoption? Curr Opinion Pediatr 2021;33:209–16.
3. Dani C. Automated control of inspired oxygen (FiO2 ) in preterm infants: Literature review. Pediatr Pulmonol 2019;54:358–63.
4. Dargaville PA, Marshall AP, Ladlow OJ, et al. Automated control of oxygen titration in preterm infants on non-invasive respiratory support. Arch Dis Child Fetal Neonatal Ed 2022;107:39–44.
5. Salverda HH, Cramer SJE, Witlox RSGM, et al. Automated oxygen control in preterm infants, how does it work and what to expect: a narrative review. Arch Dis Child Fetal Neonatal Ed 2021;106:215–21.
6. Stafford IG, Lai NM, Tan K. Automated oxygen delivery for preterm infants with respiratory dysfunction. Cochrane Neonatal Group, curatore. Cochrane Database of Systematic Reviews [Internet]. 30 novembre 2023. Disponibile presso: http://doi.wiley.com/10.1002/14651858.CD013294.pub2
7. Mitra S, Singh B, El-Naggar W, McMillan DD. Automated versus manual control of inspired oxygen to target oxygen saturation in preterm infants: a systematic review and meta-analysis. J Perinatol 2018;38:351–60.
8. Abdo M, Hanbal A, Asla MM, et al. Automated versus manual oxygen control in preterm infants receiving respiratory support: a systematic review and meta-analysis. J Maternal-Fetal Neonat Med 2022;35:6069–76.
9. Plottier GK, Wheeler KI, Ali SKM, et al. Clinical evaluation of a novel adaptive algorithm for automated control of oxygen therapy in preterm infants on non-invasive respiratory support. Arch Dis Child Fetal Neonatal Ed 2017;102:F37–43.
10. Ambulkar H, Sturrock S, Sweeney S, et al. Closed loop automated oxygen control in optimisation of mechanical ventilation in preterm infants. In: Neonatology and paediatric intensive care [Internet]. Eur Resp Soc 2020;56:2820.
11. Claure N, Bancalari E. Closed-loop control of inspired oxygen in premature infants. Seminars Fetal Neonat Med 2015;20:198–204.
12. Kaltsogianni O, Dassios T, Lee R, et al. Closed‐loop automated oxygen control in ventilated infants born at or near term: A crossover trial. Acta Paediatrica 2023;112:246–51.
13. Kaltsogianni O, Dassios T, Harris C, et al. Closed‐loop oxygen system in late preterm/term, ventilated infants with different severities of respiratory disease. Acta Paediatrica 2023;112:1185–9.
14. Salverda HH, Dekker J, Lopriore E, et al. Comparison of two automated oxygen controllers in oxygen targeting in preterm infants during admission: an observational study. Arch Dis Child Fetal Neonatal Ed 2023;108:394–9.
15. Salverda HH, Cramer SJE, Witlox RSGM, et al. Comparison of two devices for automated oxygen control in preterm infants: a randomised crossover trial. Arch Dis Child Fetal Neonatal Ed 2022;107:20–5.
16. Brouwer F, Salverda HH, Cramer SJE, et al. Comparison of two different oxygen saturation target ranges for automated oxygen control in preterm infants: a randomised cross-over trial. Arch Dis Child Fetal Neonatal Ed 2024;109:527–34.
17. Bachman TE, Onland W, Van Kaam AH, et al. Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies. BMC Pediatr 2022;22:350.
18. Wilinska M, Bachman T, Szczapa T, et al. Performance and safety of the PRICO closed-loop oxygen saturation targeting system in neonates: pragmatic multicentre cross-over study (TarOx Study). BMJPO 2024;8:e002583.
19. Dijkman KP, Mohns T, Dieleman JP, et al. Predictive Intelligent Control of Oxygenation (PRICO) in preterm infants on high flow nasal cannula support: a randomised cross-over study. Arch Dis Child Fetal Neonatal Ed 2021;106:621-6.
20. Schouten TMR, Abu-Hanna A, Van Kaam AH, et al. Prolonged use of closed-loop inspired oxygen support in preterm infants: a randomised controlled trial. Arch Dis Child Fetal Neonatal Ed 2024;109:221–6.
21. Wilińska M, Bachman T, Swietlinski J, Wasko A, Jakiel G. Quicker response results in better SpO2 control - a comparison of 3 FiO2-titration strategies in ventilated preterm infants. Ann Agric Environ Med 2015;22:708–12.
22. Van Zanten HA, Kuypers KLAM, Stenson BJ, et al. The effect of implementing an automated oxygen control on oxygen saturation in preterm infants. Arch Dis Child Fetal Neonatal Ed 2017;102:F395–9.

How to Cite



Effectiveness of automatic FiO₂ control devices in the neonatal intensive care unit: a literature review. (2026). Scenario® - Il Nursing Nella Sopravvivenza, 43(3). https://doi.org/10.4081/scenario.2026.643