Umidificazione attiva versus umidificazione passiva nella ventilazione meccanica. Revisione della letteratura
Ricevuto: 19 gennaio 2018
Accettato: 19 gennaio 2018
Pubblicato: 19 gennaio 2018
Accettato: 19 gennaio 2018
Abstract Views: 358
PDF: 890
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Autori
LARSEN R, ZIEgENFuSS T. La respirazione arti - ciale. Basi e pratica. II ed. Springer. 2011. p 105-107; p 160-165.
kELLy M, gILLIES D,TODD DA, LOCkwOOD C. Heat- ed humidi cation versus heat and mois- ture exchangers for ventilated adults and children. The Cochrane Library. 2010; 14(4):1-91.
SIEMPOS I,vARDAkAS k,kOPTERIDES P,FALAgAS M. Impact of passive humidi cation on clin- ical outcomes of mechanically ventilated patients: A meta-analysis of randomized controlled trials. Crit Care Med. 2007; 35(12):2843-2851.
kOLA A, ECkMANNS T, gASTMEIER P. Ef cacy of heat and moisture exchangers in pre- venting ventilator-associated pneumo- nia: meta-analysis of randomized con- trolled trials. Intensive Care Med. 2005; 31(1):5-11.
bRANSON R. Secretion management in the mechanically ventilated patient. Respir care 2007; 52(10):1328-42.
RESTREPO RD, wALSH bk. Humidi cation during invasive and noninvasive me- chanical ventilation: 2012. Respir Care. 2012; 57(5):782-788.
gENTILE MA, SIObAL MS. Are specialized en- dotracheal tubes and heat and moisture exchangers cost-effective in preventing ventilator associated pneumonia? Respir Care. 2010; 55(2):184-196.
MuSCEDERE J, DODEk P, kEENAN S, FOwLER R, COOk D, HEyLAND D. Comprehensive evi- dence-based clinical practice guidelines for ventilator-associated pneumonia pre- vention. J Crit Care. 2008; 23(1):126- 137.
NIëL-wEISE bS, wILLE JC, vAN DEN bROEk PJ. Humidi cation policies for mechanical- ly ventilated intensive care patients and prevention of ventilator-associated pneu- monia: a systematic review of random- ized controlled trials. J Hosp Infect. 2007; 65(4):285-291.
bOLDINI P, AMATO A. Ef cacia dei ltri/umidi- catori passivi, versus ltri/umidi catori riscaldati connessi ai respiratori mecca- nici nei pazienti adulti intubati. Scenario 2005; 22(3):13-19.
Casp Checklists [1 schermata]. Disponi- bile presso: http://www.casp-uk.net/#!ca- sp-tools-checklists/c18f8 Ultimo accesso 20/03/2014.
Scheda per la valutazione degli studi di trattamento [1 schermata]. Disponibile presso: http://www.evidencebasednursing.it/calcolatori/griglie_EBN.htm Ulti- mo accesso 20/03/2014.
Handbook EBP [1 schermata] Disponibi- le presso: http://www.evidencebasednursing.it/secretroom/HANDBOOK_EBP.pdf Ultimo accesso 20/03/2014.
LACHERADE JC, AubuRTIM M, CERF C et al. Im- pact of humidification systems on ven- tilator-associated pneumonia: a randomized multicentre trial. Am J Respir Crit Care Med. 2005; 15(10):1276- 1282.
LORENTE L, LECuONA M, JIMéNEZ A, MORA M, SI- ERRA A. Ventilator-associated pneumonia using a heated humidi er or a heat and moisture exchanger: a randomized con- trolled trial. Crit Care. 2006; 10(4):116- 123.
bOOTS RJ, gEORgE N, FAOAgALI JL, DRuERy J, DEAN k, HELLER F. Double-heater-wire cir- cuits and heat-and-moisture exchang- ers and the risk of ventilator-associat- ed pneumonia. Crit Care Med. 2006; 34(3):687-693.
NADIR OZIş T, kANAT O, OğuZüLgEN Ik, AyDOğ- Du M, HIZEL k, güRSEL G. The clinical and microbiological comparison of the use of heated humidi ers and heat and mois- ture exchanger lters with Booster in me- chanically ventilated patients. Tuberk Tor- aks. 2009; 57(3):259-267.
ALCOFORADO L, PAIvA D, SILvA F et al. Heat and moisture exchanger: protection against lung infections? Pilot study. Fisioter Pesq. 2012; 19(1):57-62.
OguZ S, DEgER I. Ventilator-associated pneumonia in patients using HME filte- rs and heated humidifiers. Ir J Med Sci. 2013; 182:651-655.
gIRAuLT C, bRETON L, RICHARD JC et al. Me- chanical effects of airway humidi cation devices in dif cult to wean patients. Crit Care Med. 2003; 31(5):1306-1311.
LELLOuCHE F, qADER S, TAILLè S, LyAZIDI A, bRO- CHARD L. In uence of ambient tempera- ture and minute ventilation on passive and active heat and moisture exchang- ers. Respir care. 2013 Oct; 8.
bOyER A, THIéRy g, LASRy S et al. Long-term mechanical ventilation and hygroscopic heat and moisture exchangers user for 48 hours: a prospective clinical, hygro metric, and bacter. Crit Care Med. 2003;
(3):823-829.
LORENTE L, LECuONA M, gALvAN R et al. Period-
ically changing ventilator circuits is not necessary to prevent ventilator-associated pneumonia when a heat and moisture ex- changer is used. Infect Control Hosp Epi- demiol. 2004; 25(12):1077-1082.
INuI D, OTO J, NISHIMuRA M. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidi cation. BMC Pulm Med. 2006; 8(6):19.
kRANAbETTER R, LEIER M, kAMMERMEIER DET, JuST HM, HEuSER D. The effects of active and passive humidi cation on ventilation-as- sociated nosocomial pneumonia. Anaes- thesist. 2004; 53(1):29-35.
AuXILIADORA-MARTINS M, MENEguETI Mg, NICOLI- NI EA et al. Effect of heat and moisture exchangers on the prevention of venti- lator-associated pneumonia in critical- ly ill patients. Braz J Med Biol Res. 2012; 45(12):1295-1300.
JAbER S, PIgEOT J, FODIL R. Long-term effects of different humidi cation systems on en- dotracheal tube patency: evaluation by the acoustic re ection method. Anesthe- siology. 2004; 100(4):782-788.
DOyLE A, JOSHI M, FRANk PET, CRAvEN T, MOONDI P,yOuNg P. A change in humidi cation sys- tem can eliminate endotracheal tube oc- clusion. J Crit Care. 2011; 26(6):637e1- 637e4.
MORAN I, CAbELLO b, MANERO E, MANCEbO J. Comparison of the effects of two hu- midi er systems on endotracheal tube resistance. Intensive Care Med. 2011; 37(11):1773-1779.
FLOREk A, NESTOROwICZ A, kOTLIÅ„SkA-HASIEC. Assessment of the ef cacy of heat and moisture exchangers with prolonged use. Anest Intens Ter. 2004 Mar;181- 184.
Agenzie di supporto
Come citare
Nykieforuk, S., Franchi, C., Aprigliano, N. F., De Padova, G., Lucarelli, D. L., & Pontrandolfo, S. (2018). Umidificazione attiva versus umidificazione passiva nella ventilazione meccanica. Revisione della letteratura. Scenario® - Il Nursing Nella Sopravvivenza, 31(4), 31–39. https://doi.org/10.4081/scenario.2014.106
Aniarti ha scelto di applicare la Licenza Creative Commons Attribuzione Non Commerciale 4.0 Internazionale (CC BY-NC 4.0) a tutti i manoscritti da pubblicare.